Grupa: Administrator
Lokalizacja:: Kłodzko JO80IK
Posty: 39687 #8121615 Od: 2013-10-18
| #24: Transient EMI Debug using Tektronix MDO4000 Mixed Domain Oscilloscope
Note that I revised this video recently. The revise video can be found here: • #76: Debug Transient EMI signal with ... This video shows an example of using the Tektronix MDO4000 Mixed Domain Oscilloscope to track down the source of a transient EMI problem on a circuit board. A near-field magnetic loop probe is used to scan the board for RF emission. The MDO is used to trigger on a transient RF source. The repetition rate of the RF burst is determined, and the source of the problem is located on the board.
TYLKO ZAREJESTROWANI I ZALOGOWANI UŻYTKOWNICY WIDZĄ LINKI » DARMOWA REJESTRACJA
_________________ Life above 50,000 MHz 73! Stanisław Kłodzko JO80IK IC-7300 + IC-9700 + (2m - 9el + 250W), (70cm - 21 el + 250W), (23cm - 55 el + 150W)
|